Input Sensor supported by IRD7100 MPT Wall Mount Speed Monitoring System?
IRD7100 MPT Wall Mount Speed Monitoring System is a 2 Channel Speed Monitoring Transmitter. It supports Non-Contact Eddy Current Based Sensor as it's Input. The Sensitivity of the Sensor should be 7.87 mV/um +/- 10%. The Sensor should be facing a notch or a toothed wheel to assist in measurement of Speed.
IRD401 is a Non Contact Sensor that can be used with IRD7100 MPT Wall Mount Speed Monitoring System
Related Articles
User Manual of IRD7100 MPT - Machinery Protection Transmitter
Introduction Introduction to IRD Mechanalysis Limited IRD Mechanalysis Limited also commonly referred as 'IRD' is a Condition Monitoring Solutions provider to the World since 1962. IRD designs, manufactures and supplies Portable Instruments and ...
Input Power required by IRD7100 MPT Wall Mount Speed Transmitter?
Unless specified otherwise, IRD7100 MPT Wall Mount Speed Transmitter requires 230 V AC, 50/60 Hz, Single Phase Grounded Power Supply as Input Power. Floating Power Supply (Potential difference between Neutral and Earth of 110 V AC) is not acceptable. ...
User Manual for IRD7100 MPT V25 for Vibration Monitoring
Introduction to IRD and IRD7100 MPT V25 IRD Mechanalysis Limited is a Company headquartered in Thane, Maharashtra, India. Also known as 'IRD' and 'The Vibration People' - IRD is involved in the Design, Manufacturing, Testing, Supply and Commissioning ...
User Manual of IRD8100 MPT when used for Vibration Monitoring
Introduction About IRD Mechanalysis Limited IRD Mechanalysis Limited is a Condition Monitoring Solutions provider to the World since 1962. Our Solutions include Online Systems for Vibration, Temperature, Speed, Gap and Turbine Monitoring. Our ...
IRD8800 MODBUS Output Register Map
Attached you will find the MODBUS RTU/MODBUS TCP/IP Register Map for Cards of the Vibration Monitoring System IRD8800. This register map applied to all cards i.e M88200, M88210, M88250 and M88280