IRD306DP is a digital vibration meter for general machinery vibration. It works with Velometer IRD531. For the full field guide, including specifications and the severity chart, see the User Manual of IRD306DP Plus.

  1. Step 1: Install 9V batteries: one battery for meters made after May 2024, or two for meters made before May 2024 (rechargeable or dry cell). Ensure a snug fit on the battery snappers with correct polarity. Prefer battery voltage about 8.2–9.8 V DC.
  2. Step 2: Connect the supplied cable to the meter and the other end to IRD531. Do not force connectors; use the guide vanes. Match the cable to your meter’s connector generation: Mini XLR (pre-June 2023), TNC (post-June 2023), or 2-pin MRS (meter) ↔ 2-pin MS (sensor) on current kits.
  3. Step 3: Fit the magnet or stinger on IRD531 and tighten fully. A loose accessory interferes with measurements.
  4. Step 4: Turn the meter ON with its power switch and use SELECT UNIT to choose Velocity (mm/s RMS) or Displacement (µm pk-pk).
  5. Step 5: Place the sensor on the equipment. Allow about 2 seconds for the reading to settle, then note it. Compare velocity readings with the ISO 10816-1 severity chart on the meter face.

Note
IRD306DP reads Vibration Velocity in mm/s RMS and Vibration Displacement in microns peak-peak.